CCA Soldering Failures Exposed: 5 Real Cases, Root Causes & Proven Fixes
CCA soldering isn't the same as copper soldering. This post dissects 5 real production failures — cold joints, Al core melt-through, galvanic corrosion, terminal creep, and flux residue attack — with root cause analysis, metallographic evidence, and actionable parameter fixes that reduced one factory's defect rate from 7.2% to 0.5%.