Skip to main content
Raytron Technical Review RESEARCH ARTICLE cca-62-specifications

CCA-62% IACS: Standard Specifications and Applications

RAYTRON技术团队1 *

1RAYTRON集团技术研究中心, 中国

*Corresponding author

Received: 2025年12月 Accepted: 2026年2月 Published: 2026年3月
DOI: 10.1234/raytron.2026.WP-02-01

1. Introduction

1.1 Grade Overview

CCA-62% is the most common and cost-effective copper-clad aluminum grade:

创建CCA-62%横截面结构示意图

MEDIA TODO
Figure Fig. 1 CCA-62% Cross-Section Structure Diagram

1.2 Market Position

CCA-62% accounts for approximately 70% of all CCA production.

2. Material Specifications

2.1 Composition

2.2 Standards Compliance

Complies with ASTM B566, IEC 62602, UL 758, and other standards.

3. Electrical Properties

3.1 Conductivity Requirements

创建导电率分布曲线

MEDIA TODO
Figure Fig. 2 Conductivity Distribution Curve

3.2 Resistance Values

3.3 Ampacity

创建电阻随温度变化曲线

MEDIA TODO
Figure Fig. 3 Resistance vs Temperature Curve

4. Mechanical Properties

4.1 Tensile Properties

4.2 Bending Properties

5. Dimensional Standards

Standard AWG sizes range from 8 AWG to 24 AWG.

6. Application Guidelines

7. Comparison with Higher Grades

CCA-62% is the standard grade, while CCA-70% and CCA-80% offer higher conductivity.

8. Conclusion

CCA-62% is the ideal choice for cost-sensitive applications, offering the best balance between conductivity and cost.

Frequently Asked Questions

What is CCA-62%?

CCA-62% is the standard grade of Copper-Clad Aluminum with a minimum conductivity of 62% IACS. It consists of an aluminum core clad with a copper layer, manufactured using the Clad & Weld process with metallurgical bonding.

What applications are suitable for CCA-62%?

CCA-62% is suitable for building wiring (where permitted), coaxial cables, grounding conductors, and low-voltage applications. It offers the best cost-to-performance ratio among CCA grades.

How does CCA-62% compare to pure copper?

CCA-62% has approximately 62% of copper's conductivity, 59% lower weight, and 35-40% lower cost. For applications not requiring maximum conductivity, it provides an excellent alternative.

What is the derating factor for CCA-62%?

CCA-62% typically requires a derating factor of 0.80 for ampacity calculations, meaning it can carry approximately 80% of the current that a same-sized copper conductor can carry.

Figures

创建CCA-62%横截面结构示意图

Fig. 1 CCA-62% Cross-Section Structure Diagram

创建导电率分布曲线

Fig. 2 Conductivity Distribution Curve

创建电阻随温度变化曲线

Fig. 3 Resistance vs Temperature Curve

Tables

Table 1 Material Composition
ComponentSpecificationTypical Value
芯材铝1350≥99.5% Al
包覆层≥99.9% Cu
铜体积比10-15%12-14%
Table 2 Electrical Properties
PropertyRequirementTypical Value
直流导电率≥62% IACS63-65% IACS
电阻率(20°C)≤2.78 μΩ·cm2.65-2.75 μΩ·cm
温度系数0.0040/°C-
Table 3 Mechanical Properties (by Temper)
TemperUTS (MPa)YS (MPa)Elongation (%)
退火(A)170-20060-9015-25
半硬(H)220-260180-2205-10
硬态(H)280-320250-2902-5
Table 4 Ampacity Comparison
AWGCopper (A)CCA-62% (A)Derating Factor
1415120.80
1220160.80
1030240.80
Table 5 Application Guidelines
ApplicationSuitabilityNotes
建筑导线适用符合当地法规
同轴电缆适用高频优势
电机绕组有限需评估温升
接地导体适用成本效益

References

  1. ASTM International ASTM B566-04: Copper-Clad Aluminum Wire ASTM (2020)
  2. IEC IEC 62602: Copper-clad aluminum for electrical purposes IEC (2022)
  3. UL UL 758: Appliance Wiring Material UL (2021)

Contact Raytron Now - Let Every Meter of Material Create Higher Value for You

Our technical team is the author of multiple Chinese national standards, with 30 years of industry experience and 34 patents, delivering professional bimetallic composite material solutions. Contact us for technical support and product quotes.

Email Us WhatsApp
Request Quote Chat on WhatsApp