Engineering application guide

MWD Downhole Sensor Wire

A downhole sensor needs its conductor, insulation and terminations to work within the specified temperature and pressure history. Evaluate the wire inside the complete assembly; material strength alone does not qualify the system.

Discuss the assembly requirements
On this page

Conductor inside the sensor assembly

  1. 1Sensor element
  2. 2Insulated NCC lead
  3. 3Feedthrough and housing

The conductor carries the signal or supply current inside the assembly. The housing and feedthrough provide the designed pressure boundary.

Illustration of sensor leads, an insulated feedthrough and a protective housing.
Sensor leads, an insulated feedthrough and a protective housing. View full-size illustration

Separate temperature and pressure histories from chemical exposure. Validate the insulation, termination and mechanical cycling with the actual lead construction.

Related conductor products

Design and testing

Duty profile
Provide temperature and pressure histories, dwell time, cycling and chemical exposure.
Mechanical construction
Specify conductor grade, strand or wire geometry, insulation build, bend radius and terminations.
System tests
Agree resistance stability, tensile/fatigue methods and insulation acceptance in the intended assembly.

Application design factors

Downhole conductor selection links electrical and joining requirements with the sensor assembly’s pressure, chemical and insulation design.

Application design record — open worksheet

Record your project requirements and observations, then download or include them in an inquiry.

ItemInformation / unitsYour input
Service envelopePressure/temperature cycles, chemical composition/concentration and duration
Supplied itemSingle wire or strand, bare conductor or insulated assembly, actual finished dimensions
Interface responsibilityWire, insulation, joining and sensor/cable qualification owners; record sealed and exposed areas
ValidationMedia/temperature/fatigue and joint test methods, sample IDs, acceptance source and open deviations
Other formats and preview
Save or restore a draft

Drafts stay in this browser. Clear inputs also removes the saved draft.

Worksheet version: RT-RFQ-WORKSHEET-1.

How should a downhole conductor be evaluated?

Evaluate conductor resistance, mechanical behavior, insulation and terminations at the specified temperatures and service media. Pressure containment is assessed at the complete housing, seals and cable feedthrough.

Discuss the assembly requirements
RFQ Request Quote Discuss your specification WhatsApp
Request Quote WhatsApp