Skip to main content
RAYTRON Logo

Using ASTM B566 in a CCA Wire RFQ

State the standard edition and the wire construction required by your purchase specification. Include diameter, material condition, copper fraction, electrical requirements and the inspection records needed for the finished wire.

On this page

Product scope

ASTM’s published scope concerns bare round copper-clad aluminum wire for electrical applications. State the required edition and material class in the RFQ; do not extend the reference to CCS, flat ribbon or foil. Check the official ASTM catalog.

RFQ and document checklist

Scroll horizontally to read all columns. Keep the conditions and units with each value.

Item Information or evidence
Wire identity Bare round CCA, diameter/tolerance, condition and the required standard edition
Copper construction Copper fraction basis, layer coverage and applicable class requirements
Electrical results Resistivity or resistance, temperature, length/section and lot identity
Mechanical/finish records Specified tensile, elongation, layer integrity and surface checks
Application checks Termination, heating and environmental tests required for the finished assembly

Review the actual document scope and test conditions against the purchase requirements. A declaration, a test report and a management-system certificate serve different purposes.

RFQ Request Quote Discuss your specification WhatsApp
Request Quote WhatsApp