Investigate the observed symptom
Use possible causes as hypotheses; compare affected and unaffected samples.
Scroll horizontally to view all columns.
| Symptom and form | Possible causes | Next check | Evidence needed |
|---|---|---|---|
| Layer separation in clad wire/strip | Interface preparation, process variation, severe forming or test damage | Compare layer continuity before/after the operation; inspect reference lot | Cross-section, lot/process history and forming/test conditions |
| Cracks, burrs or coil-feed problems | Condition, edge damage, tooling, tension or packing | Compare incoming material with formed/handled samples | Dimensions, temper/strength records, edges, spool and settings |
| Raised resistance or a local hot joint | Section change, contact resistance, oxidation or damage | Measure conductor and joint separately under the same conditions | Current/temperature record, voltage drops, joint/section images |
| PV low peel or cell damage | Wetting, coating, contamination, cell surface, profile or handling | Run controlled cell/ribbon lot comparisons; classify the failure location | Cell/ribbon lots, coating data, peel method, profile and EL images |
Keep the investigation traceable
Assign an owner and evidence requirement before closing a hypothesis.
| Record | Required detail |
|---|---|
| Defect | Location, occurrence rate, photos, sample/lot and process stage |
| Test | Agreed method, specimen, conditions, result and project acceptance requirement |
| Comparison | Affected versus reference lot with variables held constant |
| Action | Containment, proposed change, controlled verification and responsible owner |